Analisa Dan Optimasi Jaringan Fiber To The Home (ftth) Di Perumahan Ciganitri Indah Residence Kabupaten Bandung

Authors

  • Muhammad Rifqi Farisan Telkom University
  • Tri Nopiani Damayanti Telkom University
  • Adi Putra Satya Telkom University

Abstract

Abstrak Dalam penelitian ini dilakukan analisa dan optimasi jaringan FTTH di perumahan Ciganitri Kabupaten Bandung berdasarkan data dari pelanggan komplain dan juga meliputi perhitungan parameter kelayakan jaringan yaitu Power Link Budget, Rise Time Budget, dan Bit Error Rate (BER) dengan bantuan software Optisystem. Pada jaringan FTTH di perumahan Ciganitri Kabupaten Bandung telah terpasang perangkat GPON bersentral di STO Telkom Cijaura dan memiliki perangkat 1 ODC dengan passive splitter 1:32 serta memiliki 123 ONT. Hasil uji link terbukti bahwa jaringan yang telah terimplementasi FTTH ini belum memenuhi standar jaringan yang ditentukan oleh PT. Telkom. Pada panjang gelombang 1550 nm (Downstream) memiliki nilai BER sebesar 0.000203179, nilai power link budget dengan perhitungan manual sebesar -26.425 dBm, perhitungan dengan Optisystem sebesar -34.901 dBm dan rise time budget sebesar 0.2681 ns. Pada panjang gelombang 1310 nm (Upstream) memiliki nilai BER sebesar 0, nilai power link budget dengan perhitungan manual sebesar -26.803 dBm, perhitungan dengan Optisystem sebesar -29.247 dBm, dan rise time budget sebesar 0,2505 ns. Berdasarkan data dari beberapa laporan pelanggan yang komplain mengenai buruknya performa jaringan akses, maka perlu dilakukan analisis serta optimasi di beberapa titik distribusi, dan juga perlu merubah konfigurasi pada jaringan FTTH. Hasil uji link setelah optimasi terbukti bahwa jaringan yang telah terimplementasi FTTH ini sudah memenuhi standar jaringan yang ditentukan oleh PT. Telkom. Pada panjang gelombang 1550 nm (Downstream) memiliki nilai BER sebesar 8.13489x10 −35 , nilai power link budget dengan perhitungan manual sebesar -26.605 dBm, perhitungan dengan Optisystem sebesar -20.772 dBm dan rise time budget sebesar 0.2681 ns. Pada panjang gelombang 1310 nm (Upstream) memiliki nilai BER sebesar 0, nilai power link budget dengan perhitungan manual sebesar -26.983 dBm, perhitungan dengan Optisystem sebesar -3.431 dBm, dan rise time budget sebesar 0,2505 ns. Kata Kunci: FTTH, Power Link Budget, Rise Time Budget, Bit Error Rate. Abstract In this research, an analysis and optimization of the FTTH network will be carried out in Ciganitri housing in Bandung Regency based on data from customer complaints and also includes calculation of network feasibility parameters, namely Power Link Budget, Rise Time Budget, and Bit Error Rate (BER) with the help of Optisystem software. The FTTH network in Ciganitri housing in Bandung Regency has a centralized GPON device installed at STO Telkom Cijaura and has 1 ODC device with 1:32 passive splitter and 123 ONT. The link test results prove that the network that has been implemented by FTTH has not met the network standards set by PT. Telkom. At a wavelength of 1550 nm (Downstream) it has a BER value of 0.000203179, a power link budget value with a manual calculation of -26,425 dBm, a calculation with Optisystem of -34,901 dBm and a rise time budget of 0.2681 ns. At a wavelength of 1310 nm (Upstream) it has a BER value of 0, a value of a power link budget with a manual calculation of -26,803 dBm, an Optisystem calculation of -29,247 dBm, and a rise time budget of 0,2505 ns. Based on data from several customer reports that complain about the poor performance of the access network, it is necessary to analyze and optimize at several distribution points, and also need to change the configuration on the FTTH network. The link test results after optimization proved that the network that has been implemented by FTTH has met the network standards set by PT. Telkom. At a wavelength of 1550 nm (Downstream) it has an BER value of 8.13489x10−35, a power link budget value with a manual calculation of -26,605 dBm, a calculation with Optisystem of -20,772 dBm and a rise time budget of 0.2681 ns. At a wavelength of 1310 nm (Upstream) it has a BER value of 0, a value of the power link budget with a manual calculation of -26,983 dBm, an Optisystem calculation of -3,431 dBm, and a rise time budget of 0,2505 ns. Keywords: FTTH, Power Link Budget, Rise Time Budget, Bit Error Rate

Downloads

Published

2020-04-01

Issue

Section

Program Studi D3 Teknologi Telekomunikasi