Analisis Hubungan Variasi Komposisi Semen Plaster Terhadap Kuat Tekan Bahan Berdasarkan Parameter Elektrik Dan Porositas Bahan

Authors

  • Rima Jelita Fastabikul Hairat Telkom University
  • Dudi Darmawan Telkom University
  • Abrar Abrar Telkom University

Abstract

Abstrak Dalam kehidupan sehari-hari semen plester berfungsi sebagai pelapis pada dinding rumah dan bangunan. Semen harus melewati uji kuat tekan bahan sebelum digunakan. Uji kuat tekan bahan pada umumnya menggunakan metode destruktif atau merusak sampel, melalui penelitian ini dilakukan uji tekan bahan menggunakan metode non-destruktif . Pada penelitian ini diberikan bahan uji berupa semen plaster dengan dimensi 10 x 5 x 0,5 cm yang mempunyai variasi komposisi bahan dengan tiga keadaan yang berbeda. Bahan uji pertama dengan variabel bebas berupa pasir dengan massa pasir mulai 25-70 gram, sedangkan kuantitas semen dan air konstan, bahan uji kedua menggunakan variabel bebas berupa semen dengan massa semen 25-70 gram, sedang kuantitas pasir dan air konstan dan bahan uji ketiga menggunakan air sebagai variabel bebasnya versi pertama komposisi air bervariasi antara 20-40 ml dengan massa pasir dan semen 35 gram. Untuk versi kedua komposisi air adalah 15- 35 ml dengan massa pasir dan semen 25 gram. Penelitian ini memberikan hasil pengaruh variasi komposisi semen plaster terhadap parameter elektrik dan porositas bahan, dimana koefisien korelasi tertinggi yaitu R= 0,99 terdapat pada hubungan resistivitas dan komposisi bahan, setelah itu kapasitansi dengan 0,98 dan porositas 0,97 dengan kontribusi pengaruh yang tergolong sangat kuat. Pengaruh parameter terhadap kuat tekan juga memiliki nilai Koefisien korelasi (R) yang tergolong kuat, antara lain kuat tekan terhadap porositas R = 0,66 ; kuat tekan terhadap kapasitansi R = 0,65 dan kuat tekan terhadap resistivitas R= 0,6. Kata Kunci : Semen Plester, Kapasitansi, Porositas, Resistivitas, Kuat Tekan Bahan Abstract In everyday life cement plaster serves as a coating on the walls of houses and buildings. Cement must pass the compressive strength test of the material before use. The compressive strength test of materials in general uses the destructive method or damages the sample, through this research the material compressive test is done using a non-destructive method. In this study the test material was given in the form of cement plaster with dimensions of 10 x 5 x 0.5 cm which had variations in material composition with three different conditions. The first test material with the independent variable in the form of sand with a mass of sand ranging from 25-70 grams, while the quantity of cement and water is constant, the second test material uses an independent variable in the form of cement with a cement mass of 25-70 grams, while the quantity of sand and water is constant and the third test material using water as the independent variable the first version water composition varies between 20-40 ml with a mass of sand and cement 35 grams. For the second version the water composition is 15-35 ml with a mass of sand and 25 grams of cement. This study provides the results of the effect of variations in the composition of the plaster cement on electrical parameters and porosity of the material, where the highest correlation coefficient is R = 0.99 found in the relationship of resistivity and material composition, after that capacitance with 0.98 and porosity of 0.97 with the contribution of the influence classified as very strong. The effect of parameters on compressive strength also has a correlation coefficient (R) which is classified as strong, including compressive strength on porosity R = 0.66; compressive strength against capacitance R = 0.65 and compressive strength against resistivity R = 0.6. Keywords : Cement Plaster, Capasitance, Porosity, Resistivity, Compressive Strength of Materials

Downloads

Published

2020-04-01

Issue

Section

Program Studi S1 Teknik Fisika